Basic Info.
After-sales Service
Warranty for Two Years, Lifelong Maintenance.
Optical Path System
Limited Mechanical Barrel Length
Objective Lens Wheel
Four-Hole Inward Objective Lens Converter
Illumination System
Halogen Lamp 6V/20W
Total Magnification
4 Times-1600 Times
Highest Sharpness
900 Line
Signal to Noise Ratio
Less Than 42dB
Actual Observation Range
1-3000 Micron
Pixel Size
3.2 X 3.2 Micron
Product Description
Static Particle Image Analysis Equipment 1-3000 Micron
MAM-1600
IntroductionMAM-1600 particle imager is a new generation of particle image analysis equipment. MAM-1600 adopts the latest industrial-grade microscopic image acquisition system to make the observation of samples clearer. The analysis software system can analyze and calculate the "single data", "morphological parameters", "overall distribution" and other parameters of the sample, and can easily obtain rich data such as the graph of the overall distribution law of the sample and the description of the particle shape. Professional instruments and equipment for observation and analysis of various particle samples. The supporting professional particle analysis software has been upgraded and improved more humanely based on the user's opinions over the years. The computer independently analyzes the various equivalent particle sizes, X, Y tangents and other "monomer properties" of the samples, as well as length "Shape parameters" including diameter ratio and sphericity. Through further calculation, the overall distribution of this sample (including the overall distribution curve and other rich data) is obtained. The software also adds a multi-image stitching calculation mode, which doubles the number of particles involved in the analysis, thereby effectively ensuring The representativeness of the data. Finally, the sample data can be output in the form of a report (including image examples, charts, data lists, etc.), which is very convenient for testers to manage the test results.Main Advantages:As a professional particle image analysis instrument, MAM-1600 particle imager is specially designed and developed for particle or particle related industries. Its outstanding advantages are mainly reflected in the following aspects:1. Strong professionalism:Compared with the various types of image analysis instruments produced by other manufacturers, the perfect combination of the professional particle test research experience and the image theory theory of Miaoquanke is the guarantee of the professionalism of the "MAM-1600 particle imager". This product can not only scientifically describe the particle monomer of the sample, but also visually express the particle distribution using data, charts and other methods. It can perform better particle testing independently or assisted by laser particle size analyzers and other equipment.2. The data is intuitive and easy to understand, and the analysis results are clear at a glance:Common particle testing instruments include laser particle size analyzers, sedimentation particle size analyzers, etc., but the intuitive advantage of observing the morphology of samples while performing particle detection is not available in all other particle testing equipment, which can make users more comprehensive Understand the morphology, state, change process and other information of the particles. And, comparing the intuitive sample pictures can help users better understand the meaning of the data in the report.3. Wide application and high cost performance:The MAM-1600 particle imager can be used as an observation instrument to replace the traditional microscope to observe various samples, and it can also calculate various data of the sample. The operation is intuitive and simple, and the application range is very wide.The main technical parameters: Static Particle Image Analysis Equipment 1-3000 Micron
Hardware parameters |
|
Microscopic system | Optical path system | Limited mechanical barrel length |
Viewing head | 45-degree hinged trinocular head (50mm -75mm), centering telescope, 100% light-emitting photography |
45 degree hinged binocular head (50mm -75mm), centering telescope |
Eyepiece | WF10X/Ф20mm |
Long working distance plan achromatic objective lens | Magnification | Numerical Aperture (N.A.) | Working Distance (W.D.) |
10× | 0.25 | 8.1 |
25× | 0.4 | 4.8 |
40×(S) | 0.6 | 3.3 |
Phase contrast objective | 10× | 0.25 | 8.1 |
Magnification | 40×-400× |
Objective lens wheel | Four-hole inward objective lens converter |
Stage | Double-layer mobile platform: 200mmX152mm, moving range: 75mmX30mm |
Condenser | N. A. 0.4 Abbe condenser, working distance 30mm, with filter holder |
Specimen rack | Φ68mm/Φ72 or 77mmX33mm culture vessel |
Phase contrast device | 10×phase contrast ring plate center adjustable |
Focusing mechanism | Coaxial coarse and fine focusing, with locking and limit device board, fine-motion scale value: 2μm, focusing range: 30mm |
Illumination system | Halogen lamp 6V/20W, dimmable brightness |
Total magnification | 4 times-1600 times |
Camera system | Highest resolution | 2048×1536 |
Pixel size | 3.2μm×3.2μm |
Imaging element | 1/1.8 inch progress scan CMOS |
Frame rate | 6fps@2048×1536 / 10fps@1600×1200 / 15fps@1280×1024 / 30fps@640×480 |
Highest sharpness | 900 line |
Signal to noise ratio | Less than 42dB |
Sensitivity | 1.0V@550nm/lux/S |
Output mode | USB2.0 |
Actual observation range | 1-3000μm |
Software parameters |
Software function | Static collection | ake the sample topography as high-definition BMP pictures |
Picture processing | Use a variety of drawing tools to process pictures relatively simply |
Image stitching | Seamless stitching of multiple pictures, more particles can be obtained in the particle test to improve the representativeness of the test |
Automatic particle processing toolset | Automatic elimination of particle adhesion, automatic elimination of noise, automatic elimination of incomplete boundary particles, automatic filling of hollow areas of particles, automatic smoothing of particle edges and other 12 automatic processing tools. |
Scale calibration | After calibrated by the national standard micrometer, you only need to select the scale value corresponding to the objective lens for each test to directly get the actual size value of the particle. |
Single particle data | It can directly analyze more than 10 parameters such as cross-sectional area, volume, and aspect ratio of a single particle on the picture. |
Task management mechanism | Strict task management mechanism enables users to manage all test data in an orderly manner. |
Report output | The test result is output as a report, and the report style can be customized. |
Overall distribution characteristic parameters | D10, D50 (median diameter), D90, D100 and other characteristic parameters of particle distribution |
Report Parameter | Cumulative distribution of overall frequency distribution | Data tables, graphs, and histograms of the frequency distribution and cumulative distribution of particles according to number, volume, area, etc. |
Statistical average diameter | Xnl, Xns, Xnv, Xls, Xlv, Xsv and other commonly used statistical average diameters |
Shape parameters | More than 10 commonly used data that characterize the shape of particles, such as aspect ratio, bulkiness, sphericity, surface ratio, specific surface area, circumscribed rectangle parameters, etc. |
Number of statistical | Get the number of observed particles directly |
Sample thumbnail | The sample thumbnail can be displayed in the report |
Header input | The user can enter multiple information such as sample name, test unit, dispersion medium, etc. into the report header |
Custom LOGO | The user can customize the LOGO and report name, so that the output report displays the information of their own company |
Test report:
Chinese and English versions are optional
Company Profile:
Address:
Floor 4, Plant 1, Daerxun Ind. Zone, Shangmugu, Pinghu, Shenzhen, Guangdong, China
Business Type:
Trading Company
Business Range:
Instruments & Meters
Management System Certification:
ISO 9001
Company Introduction:
We adhere to the production concept of "speed, precision", and are committed to providing customers with high-precision, high-level laboratory analysis instruments. We uphold the business philosophy of "reliability, never fake", and use professional services to make cost-effective The product.
Shenzhen Qun Long Instrument Equipment Co., Ltd. (MAYZUM is our brand) is a precision laboratory instrument manufacturer integrating R&D, production and sales. We are committed to the development and commercialization of density measurement and peripheral fields. So far, we have independently developed intelligent porosity, water absorption, oil content testers, non-contact liquid density meters, portable online alcohol testers, automatic weight sorting systems, intelligent multi-group sample density measuring instruments, etc. A patented product. Today, MAYZUM′s products have served all walks of life, providing users with accurate, convenient and efficient measuring equipment.
MAYZUM′s business covers the world and has many years of experience in foreign trade. The design of each product is based on practicality, innovation and precision, in line with international standards and needs, and has developed a level of international technology with excellent technology and rich creativity, high quality, high performance and independent intellectual property rights and patents Of analytical instruments. There are a wide range of products and categories of MAYZUM instruments. The products cover general laboratory instruments, physical testing, chemical analysis, etc., such as density meters, hydrometers, viscometers, spectrometers, moisture analyzers, tension meters, thermometers, etc. From chemical, electronics, food, automobile, jewelry, research institutes and other laboratories at all levels.